Fixed Issues - 11.3.6 SP5

This article details the issues fixed in CA Workload Automation AE Release 11.3.6 SP5.
wcc114sp5p
This article details the issues fixed in CA Workload Automation AE Release 11.3.6 SP5.
GLOBAL VARIABLE TAKES LONG TIME TO STARTJOB
Problem Number: 4372
When many (excess of 20000) jobs depend on a global variable, the scheduler took a long time to determine the list of jobs that depend on the global variable. You notice a long pause between the global variable setting and the first job starting due to the global variable setting.
SCHED LEAVES JOBS IN QUE_WAIT
Problem Number: 4416
The scheduler performs machine load calculations to evaluate jobs that enter or leave the QUE_WAIT status. Depending on the timing of when a load-balancing job starts and another job completes, the part of the scheduler that evaluates a job to place it in the QUE_WAIT state competes with the part of the scheduler that evaluates queued jobs to take them out of the QUE_WAIT state. When a race condition occurred, the job remained in the QUE_WAIT status instead of executing.
SCHED UNFAIRLY DELAYS JOB START HANDSHAKES ACROSS NODE NAMES
Problem Number: 4427
When the scheduler has to start a steady stream of jobs across many different node_name machine attribute values, the scheduler might remain focused on starting jobs on a small subset of the node names. This results in delay of starting jobs on the rest of the node names.
AUTOREP -T -D DISPLAYS WRONG TIME
Problem Number: 4434
The autorep -j -t -d command displayed a wrong time zone when the server is on a UNIX or Linux platform and the client is on a Windows platform and the time zone is specified in the Olson format.
TIMEZONE IN DB IS WRONG
Problem Number: 4436
The time zone mentioned in the database was incorrect for few time zones.
SENDEVENT WASTES ONE EVENT ID FOR EACH EVENT
Problem Number: 4443
When you invoke the sendevent command to send a single event, the application server reserves two event ID values but only assigns one to the event.
EEM REPORTING UTILITY FAILS ON 32 BIT EEM
Problem Number: 4452
The CA EEM Reporting utility failed to install if the 32-bit CA EEM is installed on a Windows machine.
UNIX INSTALLER SHOWS SUMMARY SCREEN WITH WRONG DATA
Problem Number: 4459
On UNIX, when you select the Modify option to add a non-existing feature, the installer displayed wrong information about the database, ORACLE_HOME, and so on.
SCHED DOES NOT RUN JOB WITH 24 HOUR RUN_WINDOW
Problem Number: 4463
When you define a job to have a run_window attribute that spans 24 hours (for example, "00:00-23:59"), the scheduler only executed the job on the first day, but not on subsequent days.
SCHEDULER DOES NOT HONOR PRIORITY FOR QUE_WAIT/RESWAIT JOBS