Create a History Monitor

Follow these steps:
casa
Follow these steps:
  1. Click the Resources tab, open the Configure pane, expand Policies, and click
    CA SystemEDGE
    .
  2. On the Available Policies page, select the policy from the table.
  3. On the Summary page for the policy, click Monitors.
    The Summary page lists the monitors that the policy manages.
  4. Click History.
  5. On the History Monitors page toolbar, click + (New).
  6. On the Historical Details: New dialog, configure the following process settings:
    • Index
      Defines the table index to use.
    • Platform
      Specifies the platform.
    • Description
      (Optional) Defines a description of the monitor.
    • Object Class
      Specifies the object to monitor. The values in the drop-down list refer to the available MIB table.
    • Object Attribute
      Specifies the object attribute to monitor. The values in the drop-down list refer to the available attributes of the table selected as Object Class. The attribute (for example, devCapacity = 1.3.6.1.4.1.546.1.1.1.7.1.14) specifies the initial part of the MIB object (OID) to monitor with this History entry.
    • Object Instance
      Defines the object instance to monitor. This value (for example, .3 to monitor the third row in the device table (devTable) specifies the index part of the MIB object (OID) to monitor with this History entry.
    • Interval
      Defines the collection interval in a multiple of 30 seconds.
    • Buckets
      Defines the number of samples to collect.
    • Add to Performance Cube check box
      Specifies whether to collect performance cube data for this entry.
    The Maintenance Window page lets you define the following settings:
    • State
      Specifies if the monitor maintenance entry is active or inactive
    • Start Time
      Defines the start time when the monitor is switched off and the maintenance window begins.
    • Stop Time
      Defines the stop time when the monitor is switched on and the maintenance window ends.
  7. Click Save
    The History Monitor settings are saved.
  8. Click Save Policy.
    The HIstory Monitor is loaded to the Policy.