Resolved Issues in 10.4.3.1
This release contains the following fixed defects:
  • Symptom:
    DX NetOps Spectrum
    does not display any VNA NSX-T alarm on the Alarms tab only on the Events tab.
    Resolution:
    Certified 81 NSX-T alarms. Details in the attached file. (DE492680, 10.4.3.1)
  • Symptom:
    Some alarms of SilverPeak raised in
    DX NetOps Spectrum
    are not cleared when
    DX NetOps Spectrum
    receives clear events instruction from DX NetOps VNA.
    Resolution:
    Add the clear events for clearable alarms of SilverPeak.
    Follow these steps
    1. Add clear alarm code from 0x067310d5 to 0x0673113f.
    2. Add the following fields in Event format files of SilverPeak:
      closed: {S 210}
      ClearedTimeInMills: {D 158} (DE486242, 10.4.3.1)
  • Symptom:
    SpectroSERVER computes the LACP threshold and generates events and alarms when the LACP threshold value is configured as 0,0,0 for the minor, major, and critical respectively.
    Resolution:
    SpectroSERVER does not compute the LACP threshold when the LACP threshold values are configured as 0,0,0 for the minor, major, and critical respectively. (DE454087, DE491596, 32445097, 10.4.3.1)
  • Symptom:
    Notifier is sending old alarms from primary SpectroSERVER.
    Resolution:
    Improved processing of the existing alarms and avoid processing of delayed alarms due to sync issues between primary and secondary SpectroSERVER. (DE443156, 20064592, 10.4.3.1)
  • Symptom:
    Frequent getEvents (passing mh) REST calls cause OneClick WebServer crash with OutOfMemory error due to ArrayList objects consumption grows and leads to OutOfMemory.
    Resolution:
    Clear the ArrayList instance when its usage is no more required. The OutOfMemeory does not occur for frequent getEvents(passing mh) REST calls. (DE469161, 32084674, 10.4.3.1)
  • Symptom:
    Due to changes in  10.4.2, if SRadmin is not selected, the first line is skipped if there is no empty line in the captured running-config file.
    Resolution:
    This scenario was taken care of while SRadmin was not selected for NCM. (DE481216, 32272653, 10.4.3.1)
  • Symptom:
    SRM NCM buckets are not processed properly with data encoding errors.
    Resolution:
    Code changes are made to process the SRM NCM buckets properly. (DE484263, , 10.4.3.1)
  • Symptom:
    If updates are received by AlarmNotifier before a new alarm notification is sent, then the SET script uses updated alarm attributes for notification.
    Resolution:
    If MERGE_ALARM_UPDATES is set to false in .alarmrc file, then SET script uses the original alarm attribute values. (DE483244, DE400611, 32369198, 10.4.3.1)
  • Symptom:
    Few monthly maintenance schedules such as "First Sunday of every month" are not working as expected.
    Resolution:
    Code changes are made to trigger the schedules as per the recurrence data provided. (DE490437, 32480350, 10.4.3.1)
  • Symptom:
    With changes introduced in
    DX NetOps Spectrum
    10.4.2.1 to support Service Units in Linux the processd.pl script was changed to execute systemctl which does not exist on the Windows platform and therefore running the script does nothing now on windows.
    Resolution:
    Code changes are made to run the correct script on the windows and Linux platforms. (DE493404, 10.4.3.1)
  • Symptom:
     Authentication Failed for Local users only.
    Resolution:
      Code changes are made to authenticate the local users is successful for Local users. (DE493405, 32532384, 10.4.3.1)
  • Symptom:
    For Huawei VRP models, the Information tab OneClick view is not showing more than 100 entries and for other model types some times showing empty lines.
    Resolution:
    For Huawei VRP models, the Information tab OneClickview shows more than 100 entries, and for other model types, does not show empty lines. (DE485083, , 10.4.3.1)
  • Symptom:
    SpectroSERVER crashes while handling V3/V2 traps if the overCommStr string points to NULL.
    Resolution:
    Code changes are made to stop SpectroSERVER from crashing while handling V3/V2 traps even if the overCommStr string points to NULL.  (DE482425, 32303171, 10.4.3.1)
  • Symptom:
    SPM Tests are missed/not visible after SpectroSERVER restart
    Resolution:
    Code changes are made to read SPM tests ahead of Inventory loading. (DE494502, 32538195, 10.4.3.1)
  • Symptom:
    Model Class was not set as per the CSV file when the customer is importing data using the CSV file from the Device Certification dialogue.
    Resolution:
    Corrected the code so that the correct model class is set as per the CSV file. (DE494229, , 10.4.3.1)
  • Symptom:
    The dbmigrate utility crashed during
    DX NetOps Spectrum
    upgrade to 10.4.3 with the dbmigration option.
    Resolution:
    Code changes are made to fix the dbmigrate crash by accessing the valid memory locations. (DE495917, 32586359, 10.4.3.1)
  • Symptom:
    NCM running configuration failed in the case of large configuration files.
    Resolution:
    NCM GRPC communication channel maximum receives message size set to default value 4MB. Changed the Receive message size to 64MB. (DE496405, 32582829 , 10.4.3.1)
  • Symptom:
    Crash observed in Qualys security scan in OpenSSL zlib_stateful_init API.
    Resolution:
    zlib_stateful_init method is part of OpenSSL in the case of OpenSSL build with zlib. Rebuilt OpenSSL without zlib. (DE496191, 10.4.3.1)
  • Symptom:
    Null Pointer Exception for IS_COMPOSED_OF relation deletion in catalina.out file.
    Resolution:
    Code changes are made to avoid Null Pointer exceptions when you delete the IS_COMPOSED_OF relation. (DE494693, 32534426, 10.4.3.1)
  • Symptom:
    External connection requests on 14023 port cause the Socket FDs growth on the SpectroSERVER process.
    Resolution:
    Code changes are made to identify invalid socket FDs and close them on external connect requests. (DE490222, 32463513 , 10.4.3.1)
  • Symptom:
    List type attribute read failure causes memory leak.
    Resolution:
    Code changes are done to avoid memory leak when the List type attribute read fails. (DE488887, 32455948, 10.4.3.1)
  • Symptom:
    OnlineBackup fails to synchronize the primary SpectroSERVER SSdb file to Secondary SpectroSERVER.
    Resolution:
     After triggering OLB action it synchronizes the primary SpectroSERVER SSdb file to Secondary SpectroSERVER.  Note: If OLB fails,  Add "export PROCESSD_LCOPY=TRUE" env variable to $SPECROOT/lib/SDPM/processd_init.sh file on secondary SpectroSERVER machine. (DE485890, 10.4.3.1)
Resolved Issues in 10.4.3
This release contains the following fixed defects:
  • Symptom:
    The total outstanding alarm counter in the VNM model is showing incorrect values.
    Resolution:
    Code changes are made to display correct values. (DE460280, 31861150, 10.4.3)
  • Symptom:
    Tomcat startup is taking more than 2 hours for large setups.
    Resolution:
    Code changes are made to complete the Tomcat startup within 15 mins for large setups. (DE470271, 32105397, 10.4.3)
  • Symptom:
    NCM Approval Workflow does not work for Repair Task.
    Resolution:
    Code changes are made so that the Repair Task honors the NCM Approval Workflow. (DE471598, 32121575, 10.4.3)
  • Symptom:
    After device reconfiguration with some new Interfaces, the LACP configuration is not correct.
    Resolution:
    Device reconfiguration with the new Interfaces shows the correct LACP configuration. (DE478335, 32202240, 10.4.3)
  • Symptom:
    ArchMgr crashes very frequently.
    Resolution:
    Code changes are made to stop ArchMgr from crashing. (DE482754, 10.4.3)
  • Symptom:
    Multiple issues
    • Tomcat startup is taking a long time >1hr.
    • LDAP Authentication issue and users cannot log into OneClick Client.
    • SpectrumInsideView not  monitor DSS environment having more than 6 landscape
    Resolution:
    • Tomcat starts up within 10mins.
    • No more LDAP Authentication issues and users are logged in to the OneClick client.
    • SpectrumInsideView can monitor the DSS environment having more than six landscape (DE482379, 32307779, 10.4.3)
    (DE482379, 10.4.3)
  • Symptom:
    When the LDAP server gets changed behind a Load-Balancer, it causes an LDAP authentication issue and users cannot log into the OneClick client.
    Resolution:
    Code changes are made to resolve the authentication issue. (DE482381, 32307776, 10.4.3)
  • Symptom:
    For many applicable interfaces, the interface status is shown as N/A though the corresponding OID is sending value.
    Resolution:
    Code changes are made to fix the issue. (DE479028, DE482812, 32217811, 10.4.3)
  • Symptom:
    Telnet/SSH window requires the user to click/tab in order to enter user login and password.
    Resolution:
    Code changes are made to insert the cursor at the login prompt. (DE483844, 32304014, 10.4.3)
  • Symptom:
    The datacenter is not shown in the vCenter hierarchy and the datacenter table in the OneClick console.
    Resolution:
    Identified that the datacenter model exists in the wrong landscape. After deleting that model and restart the gateway probe, the datacenter is modeled in the correct landscape and it is updated in the datacenter table in the OneClick view. (DE482836, 32320663, 10.4.3)
  • Symptom:
    Modeling Gateway is merging the child node with the parent node during importing if the child node has the same name as the parent.
    Resolution:
    Now both parent and child nodes with the same names are successfully imported. (DE478902, 32239916, 10.4.3)
  • Symptom:
    Alarm Notifier crashes while fetching the pcause data.
    Resolution:
    Code changes are made to prevent Alar Notifier from crashing while fetching the pcause data. (DE478110, 32215508, 10.4.3)
  • Symptom:
    "Component Details --> Performance " will not show memory-related data  and it takes time to populate CPU related data for  Host_SystemEdge model type devices
    Resolution:
    "Component Details --> Performance " shows CPU and memory-related data for  Host_SystemEdge model type devices (DE483320, 32262200, 10.4.3)
  • Symptom:
    Model Class from Device Certification is not honored for HuaweiVRP devices
    Resolution:
    Model Class from Device Certification is honored for HuaweiVRP devices after adding auto_lock_model_class=false in .vnmrc file (DE485119, 32307940, 10.4.3)
  • Symptom:
    SDC TrapX not sending traps to associated IP address of filter domain. Trapx always sending traps to the last resolved IP address of the domain name of the last filter present in the "TrapX.config" file.
    Resolution:
    SDC TrapX should send traps to the associated destination IP address of the resolved hostname of the filter that is present in the "TrapX.config" file. (DE483529, 32321638, 10.4.3)
  • Symptom:
    The deletion of empty and invalid v3 profiles was causing the issue.
    Resolution:
    Disabling the deletion of empty and invalid v3 profiles. (DE482657, 32281705, 10.4.3)
  • Symptom:
    Negative PDU length causes SpectroSERVER crash
    Resolution:
    SpectroSERVER does not crash on negative PDU length. (DE485345, 32387947, 10.4.3)
  • Symptom:
    we are able to make a successful association between the blade and ESX host devices. We can achieve this behavior after matching serial numbers of both Blade and UCS Host device/container instead of UUID.
    Resolution:
    we are able to make a successful association between the blade and ESX host devices. We can achieve this behavior after matching serial numbers of both Blade and UCS Host device/container instead of UUID. (DE451029, 20291108, 10.4.3)
  • Symptom:
    Periodically, the customer is getting an error on the routers stating "too many probes" when trying to creating SPM tests.
    Resolution:
    Fixed the issue where-in the function which tests for existing probes is not getting called. (DE481503, 32249986, 10.4.3)
  • Symptom:
    Occasionally whenever we discover the device interface names are the models are not getting populated.
    Resolution:
    In one of the corner cases, interface names are not getting updated correctly. Added code to fix it. (DE468489, 32056395, 10.4.3)
  • Symptom:
    The
    DX NetOps Spectrum
    runs into a performance issue when it receives too many traps through South-Bound Gateway(SBG).
    Resolution:
    Code changes are made to avoid performance issues when it receives too many traps through South-Bound Gateway(SBG). (DE479293, 32235518, 10.4.3)
  • Symptom:
    When you try to send an Alarm mail and you choose the Option To: Cc, Bcc. You can select the mail address in the window but you cannot confirm because the OK button is missing.
    Resolution:
    Now OK butting is showing to confirm selected mail addresses.  (DE470293, 32107571, 10.4.3)
  • Symptom:
    SRM throws null pointer exception during tomcat startup
    Resolution:
    SRM Nullpointer exception is handled during the tomcat startup. (DE484254, DE484297, 10.4.3)
  • Symptom:
    Unable to create containers in webapp, it errors out saying "model does not exist"
    Resolution:
    Provide WebApp configuration to resolve the issue.Permanent Code fix is part of US717916 - webswing-VmArgs upgrade fix and model_bits args addition (10.4.3) (DE481428/ DE480814/ DE468052, 32244408, 10.4.3)
  • Symptom:
    Manual connections under nested container are not exported by the modeling gateway
    Resolution:
    Manual connections under nested container are exported by modeling gateway (DE469388, 32056847, 10.4.3)
  • Symptom:
    The stack trace is getting printed in the tomcat log when a restricted user tries to access the REST API.
    Resolution:
    Added proper log handling to remove the trace and print the proper log. (DE487699, 32427369, 10.4.3)
  • Symptom:
    Interface models are renamed after VNA integration full sync
    Resolution:
    Existing interface models are retained with the same name after VNA integration full sync (DE488002, 32437366, 10.4.3)
  • Symptom:
    Huge notification queue data dumped into VNM.out
    Resolution:
    Making pending queue dumping configurable through the .vnrmc option. (DE485366, 32390485, 10.4.3)
  • Symptom:
    Vulnerability: Stored Cross-Site Scripting (XSS) is observed when the Lock Debugging page is accessed. When logging into OneClick it is possible to inject code and have this code executed when accessing subsequent pages.
    Resolution:
    Vulnerability: Stored Cross-Site Scripting (XSS) is resolved. (DE484430, 32354525, 10.4.3)