U1005

Reason:
ca1tms
Reason:
This abend is uniquely associated with TMSCOPY. The TMSCOPY output provides more information. The following reason codes are issued in register 15:
Code
Reason
Action
04
This indicates a bad DSNB record.
Use TMSPTRS to identify the error and then manually correct the bad DSNB record.
08
This indicates a bad TMC record.
Use TMSUPDTE to correct the bad TMC record.
0C
The number of TMC Volume or DSNB records did not match the total number generated in the Control records.
See the report for more specific error information and correct accordingly.
10
CA 1
is not in the proper operating mode to execute a RESTORE operation.
CA 1
must be inactive or batch active. Take the appropriate corrective action.
14
An invalid TMC Volume or DSNB record was encountered during a BACKUP or RESTORE operation.
See the report for more specific error information and correct accordingly.
18
An I/O error occurred while reading a file. The output provides more information.
See the sample TMSCOPY JCL for correct DCB information.
1C
During RESTORE processing, the AUDIT DD was specified as DUMMY.
Even if Audit records are not going to be processed in the RESTORE, a valid formatted Audit must be available to TMSCOPY.
24
During a copy operation, a bad value was detected in control record 5 of a BLOCKSET audit file.
Contact
CA 1
Support for assistance in correcting this error.
28
The number of AUDIT records read is not equal to the number of Audit records generated.
Verify that the AUDIT dataset was formatted properly and that TMSFORMT did not abend with a SD37/SB37. If the Audit dataset was copied or moved, verify that the operation did not abend with a SD37/SB37.
Alternatively, verify using TMSBINQ that the number of records generated (TMAUDIT1) has not been updated with incorrect values.