TMSVMEDT Messages

ca1tms
 
 
- BYPASSED -
 
 
Reason:
 
Due to other errors, the flagged control statement has been bypassed.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
*** DSN REC INVALID EOD
 
 
Reason:
 
A DSN= statement was found as the last control statement in the VPD.A V= statement should follow the DSN= statement. The total number of DSN= statements ignored are indicated in the value xxx.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
*** E= EXPIRATION DATE IS EXPIRED
 
 
Reason:
 
An expiration date less than or equal to the execution date was found on the flagged statement.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
*** INVALID END OF DATA - VAULTS=nnnn
 
 
Reason:
 
The control statement contains VAULTS= which is invalid. All VAULTS= statements must precede DSN and V= statements.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
*** KEYWORD SPECIFIED MORE THAN ONCE
 
 
Reason:
 
The keyword listed is a duplicate.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
*** MAX= INVALID FOR nnnnn VAULT
 
 
Reason:
 
The MAX= keyword was coded for LIB or LIBR which is invalid.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
*** MISSING xxx= QUALIFIER
 
 
Reason:
 
The qualifier listed is missing a required value.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
*** PATTERN MASKING ERROR:
 
 
Reason:
 
The data set name contains an invalid pattern masking specification.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
*** PREVIOUS nnn DSN RECORDS IGNORED
 
 
Reason:
 
An error was found while processing the vault movement statements.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
*** SEPDSN AND JOB QUALIFIER INVALID
 
 
Reason:
 
SEPDSN was specified on the DSN= statement with a JOB= keyword.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
*** SYNTAX INVALID
 
 
Reason:
 
The flagged control statement has invalid syntax, such as a missing or bad delimiter.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
*** UNKNOWN OR INVALID RECORD SEQUENCE, EXPECTED DSN RECORD.
 
 
Reason:
 
After the last V= statement, a control statement was read that did not begin with DSN=.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
*** UNKNOWN RECORD
 
 
Reason:
 
The control statement does not begin with DSN=, V=, VOL=, or CDSN=.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
*** VAULT NAME RECORD MISSING
 
 
Reason:
 
No VAULTS= statement was found in the VPD.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
*** VAULT NAME (xxxx) INVALID.
 
 
Reason:
 
The vault name shown is too long. The maximum length for a vault name is 4 characters. If the vault name on the control statement is greater than 7 characters long, only the first 7 characters are shown in the message.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
*** xxx VAULT PATTERNS INVALID.
 
 
Reason:
 
The specified number of VPD entries are invalid.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
CA 1
IS NOT ACTIVE
 
 
Reason:
 
CA 1
was inactive. TMSVMEDT requires
CA 1
to be active or batch active.
 
Action:
 
Initialize
CA 1
using TMSINIT and resubmit the job.
 
CR= AND E= INVALID FOR SAME VAULT
 
 
Reason:
 
These combinations are not valid on the same V= statement.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
DUP RETENTION (xxx) FOUND
 
 
Reason:
 
Duplicate V= statements were found in a pattern; xxx shows the retention value, such as C=.
 
Action:
 
Correct the control statement(s) resubmit the job.
 
DUPLICATE DATA SET NAME FOUND
 
 
Reason:
 
The same data set name was specified twice in the VPD.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
FIRST RECORD OF THE TMC IS NOT TMSCTL#1
 
 
Reason:
 
During a sequential read of the TMC, the first record did not contain the correct Control Record. The TMC dynamically allocated by TMSVMSRT is invalid.
 
Action:
 
See the 
Programming
 and for assistance, contact Technical Support at http://ca.com/support.
 
INVALID DATEFMT SPECIFICATION
 
 
Reason:
 
The DATEFMT= value coded on the JCL parameter is invalid.
 
Action:
 
Correct the JCL and resubmit the job.
 
INVALID KEYWORD, NEAR COLUMN nn
 
 
Reason:
 
Incorrect keyword specification has been detected at the indicated position.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
INVALID PARM
 
 
Reason:
 
The parameter listed is not a valid JCL parameter for TMSVMEDT.
 
Action:
 
Correct the JCL and resubmit the job.
 
INVALID SYNTAX, NEAR COLUMN nn
 
 
Reason:
 
Invalid control statement syntax has been detected at the indicated position.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
INVALID VALUE
 
 
Reason:
 
A retention value was found to be invalid (such as, more than 255cycles).
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
LU= and E= INVALID FOR SAME VAULT
 
 
Reason:
 
These combinations are not valid on the same V= statement.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
MAX V=STMTS EXCEEDED
 
 
Reason:
 
A pattern specifies more than 28 consecutive V= statements. A maximum of 28 consecutive V= statements is allowed for a given group of DSN control statements.
 
Action:
 
Correct the control statement(s) and resubmit the job.
MOVEMENT STATEMENT OUT OF SEQUENCE
 
Reason: 
The Vault Pattern Control Statement (V=xxxx) is missing or out of sequence.
 Action: 
 
Correct the control statement(s) and resubmit the job. 
 
NO RETENTION FOUND
 
 
Reason:
 
A pattern does not reflect the retention for a given location.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
OUT OF MEMORY FOR DSN ENTRY
 
 
Reason:
 
No more storage was available for the data set name entry.
 
Action:
 
Increase region in JCL and resubmit the job.
 
OUT OF MEMORY FOR VAULT MOVEMENT TABLE
 
 
Reason:
 
No more storage was available for the data set name entry.
 
Action:
 
Increase region in JCL and resubmit the job.
 
OUT OF MEMORY FOR VAULT NAME TABLE
 
 
Reason:
 
No more storage was available for the data set name entry.
 
Action:
 
Increase region in JCL and resubmit the job.
 
PATTERN MASKING MODULE CTSPM CANNOT BE LOADED
 
 
Reason:
 
The load for module CTSPM failed.
 
Action:
 
CTSPM should reside in CAI.CTAPLINK. Check the link list concatenation or add the appropriate load library to the TMC STEPLIB ddname and resubmit the job.
 
PREVIOUS DSN MISSING VAULT RECORD
 
 
Reason:
 
No V= statement was found after a DSN= statement.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
STORAGE NOT AVAILABLE FOR CTSPM INTERFACE
 
 
Reason:
 
A request for storage failed during CTSPM initialization.
 
Action:
 
Correct the JCL and resubmit the job.
 
STORAGE NOT AVAILABLE FOR TMSDATE INTERFACE
 
 
Reason:
 
A request for storage failed during TMSDATE initialization.
 
Action:
 
Correct the JCL and resubmit the job.
 
STORAGE NOT AVAILABLE FOR TMSPRINT INTERFACE
 
 
Reason:
 
A request for storage failed during TMSPRINT initialization.
 
Action:
 
Correct the JCL and resubmit the job.
 
STORAGE NOT AVAILABLE FOR TMSVMSRT INTERFACE
 
 
Reason:
 
A request for storage failed during TMSVMSRT initialization.
 
Action:
 
Correct the JCL and resubmit the job.
 
TMC RECORD COUNT OFF xxxxxx RECORDS READ - PROCESSING TERMINATED
 
 
Reason:
 
The number of Volume records read does not equal the number of Volume records on the TMC.
 
Action:
 
Execute TMSPTRS and correct any reported errors before resubmitting the job.
 
TMMDATE OPEN ERROR/FAILED
 
 
Reason:
 
An error occurred while trying to initialize the TMSDATE interface.
 
Action:
 
See the reason feedback codes listed for the TMMDATE macro in the 
Programming.
 
 
TMSRPT DDNAME MISSING
 
 
Reason:
 
The TMSRPT report ddname could not be found or opened.
 
Action:
 
Correct the JCL and resubmit the job.
 
TMSVMEDT ENDED WITH ERROR: FDBK=0 CTMDATE OPEN ERROR
 
 
Reason:
 
Invalid EXEC parameter field in the JCL.
 
Action:
 
Correct the parameter in the EXEC statement and resubmit the job.
 
TMSVMEDT ENDED WITH ERROR: FDBK=x message.text
 
 
Reason:
 
An error occurred during TMSVMEDT processing. The FDBK value and message printed describe the problem.
 
Action:
 
See the message text to correct the error and resubmit the job.
 
UNKNOWN RECORD
 
 
Reason:
 
A record did not begin with *, VAULTS=, DSN= or V=, or the VAULTS= definition was not the first control statement.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
VAULT NAME UNDEFINED
 
 
Reason:
 
A V= statement reflects a name not on the VAULTS= statement.
 
Action:
 
Correct the control statement(s) and resubmit the job.
 
VR= AND E= INVALID FOR SAME VAULT
 
 
Reason:
 
These combinations are not valid on the same V= statement.
 
Action:
 
Correct the control statement(s) and resubmit the job.