Debug flags in Server
Manager
Debug
flags in Server Manager and their descriptions
describes the debug flags in
Server Manager
.
Debug flag
| Value
| Description
|
|---|---|---|
EnableHVMonitoringDebug
| TRUE
| Indicates that Hyper-V debugging is enabled during monitoring.
|
EnableOpenStackMonitoringDebug
| TRUE
| Indicates that OpenStack debugging is enabled during monitoring.
Default: False
|
EnableOpenStackDiscoveryDebug
| TRUE
| Indicates that OpenStack debugging is enabled during discovery.
Default: False
|
EnableSPMonitoringDebug
| TRUE
| Indicates that WMI Service Process debugging is enabled during
monitoring.
|
EnableClusterDiscoveryDebug
| TRUE
| Indicates that debug is enabled for Cluster discovery.
|
EnableServiceProcessCfgDebug
| TRUE
| Indicates that debug for Service Process Monitoring and
Discovery using Templates configuration has been enabled.
|
EnableVMwareMonitoringDebug
| TRUE
| Indicates that debug for VMware SNMP monitoring has been
enabled.
|
EnableCredentialsCfgDebug
| TRUE
| Indicates that debug for Credentials configuration has been
enabled.
|
EnableVMwareVCDiscoveryDebug
| TRUE
| Indicates that debug for the VMware VC discovery has been
enabled.
|
EnableVMwareVMMonitoringDebug
| TRUE
| Indicates that debug for the VMware VC monitoring has been
enabled.
|
IsDebug
| TRUE
| Enables all debug flags globally. Setting the value to TRUE
would fetch information about all the debug flags, leading the server log to
grow exponentially.
This flag must be used only when recommended.
|
EnableEMCMnRMonitoringDebug
| Enable or disable debugging for all the elements monitored using
EMC M&R.
This is global flag. If this flag's value is TRUE, then there is
no need to enable any other flag for debug logging. If you change the flag's
value, do a reconfiguration in Server Manager to make the change effective.
| |
EnableEMCMnRFCSwitchPortMonitoringDebug
| Enable or disable logging of messages for EMC M&R
FibreChannelSwitchPort monitoring. If you change the flag's value, do a
reconfiguration in Server Manager to make the change effective.
| |
EnableEMCMnRPhysicalDiskMonitoringDebug
| Enable or disable logging of messages for EMC M&R
PhysicalDisk monitoring. If you change the flag's value, do a reconfiguration
in Server Manager to make the change effective.
| |
EnableEMCMnRSparePhysicalDiskMonitoringDebug
| Enable or disable logging of messages for EMC M&R
SparePhysicalDisk monitoring. If you change the flag's value, do a
reconfiguration in Server Manager to make the change effective.
| |
EnableEMCMnRFCSwitchMonitoringDebug
| Enable or disable logging of messages for EMC M&R FCSwitch
monitoring. If you change the flag's value, do a reconfiguration in Server
Manager to make the change effective.
| |
EnableFCArrayPortMonitoringDebug
| Enable or disable logging of messages for EMC M&R
FCArrayPort monitoring. If you change the flag's value, do a reconfiguration in
Server Manager to make the change effective.
| |
EnableEMCMnRRAIDGroupMonitoringDebug
| Enable or disable logging of messages for EMC M&R RAIDGroup
monitoring. If you change the flag's value, do a reconfiguration in Server
Manager to make the change effective.
| |
EnableCloudifyDiscoveryDebug
| Indicates that debug is enabled for orchestrator discovery.
| |
EnableVCDDiscoveryDebug | Indicates that debug is
enabled for vCloud Director discovery. | |
EnableVCDMonitoringDebug | Indicates that debug is
enabled for vCloud Director monitoring. |