Reloading weight and event filter elements
When you modify the content of a weights or event filter import datafile that has already been loaded by the source
Global Manager
, you must issue an sm_adapter
command to force the Global Manager
to reload the elements defined in the weights
and event filter import datafiles. The sm_adapter
command invokes the drivers that load the elements defined in these datafiles.To reload business weight and event filter elements:
- In the installation area from which the sourceGlobal Manageris invoked, go to theBASEDIR/smarts/bin directory and type the following command:sm_adapter -s <Global Manager name> ics/ICS_RemoteConfig.aslsm_adapter -s INCHARGE-SA ics/ICS_RemoteConfig.asl
- If prompted for a username and password, specify your user account; for example, to specify the default administrative account, type usernameadminand passwordchangeme.Each time a weights or event filter import datafile is reloaded, the new definition set replaces the current one. Any eliminated definition from a weights or event filter import datafile will remove that definition from theGlobal Manager’s memory.